PROPORTIONING IN EXCELLENCE.
Phone 346 262 6075 Mail info@firedos.com
DE | EN

Optimized flow pattern, maximum range.

Firefighting monitors for water or extinguishing foam

FireDos monitors can deliver thousands of gallons of water per minute in excess of 500 feet. The innovative, flow-optimized ‘Oval Flat Design’ ensures minimum pressure loss, enabling maximum throw and range for the monitors.

  • For flow rates from 132 to 15,850 gpm
  • Manually or electrically controlled
  • Adjust the extinguishing agent flow rate during operation and at full pressure

One of the most compact fire monitors with electric drives

M1 monitor for stationary fire protection and fire trucks

  • For extinguishing agent flows up to 528 gpm
  • Compact and lightweight: 18,5 x 10 x 14,17 inch, approx. 26.4 lbs
  • For stationary fire protection and for installation on fire trucks
  • Highly configurable in terms of nozzles and extinguishing agent flow
  • For rapid extinguishing of large areas with the optional flat jet nozzle
  • On request with 24V CAN-BUS control for connection to fire trucks or with control for stationary fire protection

We are setting new standards with our new M1 fire monitor: it is one of the world's smallest fire monitors with electric drives. Two sizes are available, with 264 and 528 gpm. You can also choose between two different nozzles. The compact M1 is ideal for stationary fire protection in waste bunkers, recycling plants, or on helicopter landing pads. 

learn more

NEW AND FOR FREE

FireDos lunch & learn

Do you like to learn more about firefighting with foam?

We bring our experts to you and train your team. No need to care for catering. We also bring lunch for free. 

Learn more

Someone sitting at a laptop and eating

Advantages

Safe investment

Robust, reliable, sturdy, built-to-last

Easy operation and integration

Electrically operated and compatible with thermal imaging systems

Versatile

Wide swiveling ranges, adjustable extinguishing agent flow rate

Request a quote

You are interested in our fire monitors? We will be happy to help you along. Request a non-binding quotation from us!  

Start inquiry

Stay informed

Stay informed

The FireDos newsletter always keeps you well-informed. Stay up-to-date on all aspects of fire extinguishing technology.   

Subscribe now
Play
Monitor nozzles

The monitor nozzle shapes the jet

Regardless of using water or foam, manual or electrical controls, FireDos offers the perfect nozzle for your firefighting monitor application.

MPN / AMPN multi-purpose nozzles
Flat spray
RFP foam pipe
FPD / AFPD foam pipe with deflector

MPN / AMPN Multi-purpose nozzles

  • Discharge water or low-expansion foam premix
  • Adjustable extinguishing agent flow rate
  • Stepless adjustment between hollow jet and spray jet
  • Circle-shaped spray jet, optional nozzle design for shaping a flat and wide spray jet

MPN / AMPN Multi-purpose nozzles

  • Flat jet with a modified spraying angle (special version)
  • Available in sizes M1, M2, M3, and M4

RFP Foam pipe

  • Add-on to the multi-purpose nozzles
  • Temporary discharge of low-expansion foam
  • Discharge pure water

FPD / AFPD Foam pipe with deflector

  • Discharge low-expansion foam
  • Wide jet produces a foam blanket
  • With the deflector in place, a wide jet can be produced for large-surface foam application
  • Discharge pure water
  • Wide swiveling ranges

Depending on the equipment version, the following maximum swiveling ranges are available:

  • Horizontal (left/right): 360° (350° at DC drives)
  • Vertical (up/down): +/-90°, depending on the selected version
  • Sturdy and long-lasting

The media-exposed components are designed for working pressures up to 232 psi with lubricated-for-life bearings. Reduced friction resistance seals guarantee ease of movement even after long downtimes.

  • Adjustable flow rate

All type series are available with nozzles and foam pipes allowing flow rate adjustment even during operation and at full pressure

FireDos fire monitor with wide swivel range
FireDos fire monitor side view
FireDos fire monitor with adjustable flow rate

Configure your monitor

Typical monitor applications

FireDos monitors are used wherever extinguishing agents for fire class A and B are applied, outdoors and indoors. Typical fields of application include tank farms, waste incineration plants, jetties and aircraft hangars.

Application fields monitors

Fire monitor and nozzle selection

Type series
M1 M2 M3 M4 M5 M7 M9 M12
Max. extinguishing agent flow rate in l/min 2000 2500 4500 8000 12000 24000 40000 60000
Multi-purpose nozzle (MPN) x x* x* x* x* x    
Multi-purpose nozzle with adjustable  
extinguishing agent flow rate (AMPN)
x x x x x x x x
Removable foam pipe (RFP)   x x x x x x x
Foam pipe with deflector (FPD)   x x x x x    
Foam pipe with deflector and adjustable 
extinguishing agent flow rate (AFPD)
  x x x x x    
Flat jet nozzle x x x x        
* Valid for selected product and drive types. See separate datasheet and FM Approval Guide entry.

Start testing our fire monitors – in the virtual world of FireDos!

Explore the virtual world of FireDos and test our monitors in simulated application settings. Augmented Reality puts our monitors into your hands – just a click away.

Please note the following for easier navigation:

  • Use the number buttons to show the individual camera positions.
  • Use the buttons 'q' and 'e' to navigate up and down.

We look forward to meeting you in our virtual world!

Enter virtual FireDos world

Monitor in virtual world of FireDos

Integration into automated fire extinguishing systems

For remote-controlled operation in stationary extinguishing systems, our monitors can be equipped with functional controls. Integration into existing thermal imaging systems is possible. Users benefit from minimum reaction times and maximum reliability.

  • For all types of electric drives
    Whether direct current, alternating current or three-phase current, regardless of voltage or frequency – we offer control systems for all types of electric drives.

  • Numerous control functions
    Remote control of all monitor functions is possible – from moving to the park and working positions, through the oscillation function, to the automatic self-test.

  • Remote service
    Via the integrated gateway, the FireDos service can access the control system remotely, if required, and following consultation with the customer, to provide support during commissioning and maintenance work.
  • Portable and stationary control units
    Control is carried out via mobile or permanently mounted control panels. Portable radio remote controls and/or wired control panels are available for operation.
  • Customised Integration of external systems
    Our extinguishing monitors process signals from early fire detection and flame detection systems from various manufacturers. They also support signal exchange with higher-level control systems and fire alarm control panels.

  • Intuitive control, absolute precision: The SCON operating interface
    At the heart of our SCON control system is the intuitive user interface for the quick and precise Operation of the FireDos monitors during maintenance and commissioning.
  • Full system control
    Switch seamlessly between the individual monitors in your system and access detailed settings, Parameters or system information as required. The clearly structured menu navigation makes configuration and maintenance easier than ever before.
FireDos HMI monitor control

SCON: The smart control system for fire monitors

Precision firefighting taken to a whole new level: with FireDos’ SCON stationary monitor control system, you have your fire protection system under control at all times, wherever you are. Our modular concept offers you a tailor-made solution that adapts perfectly to the requirements of your premises – from a single unit to an extensive network.

Modular and scalable for any system size

At the heart of the system is the SCON-MAIN control cabinet with integrated PLC. From here, you control the entire network. Easily expand your system with up to seven SCON-SUB control cabinets, each Controlling an additional extinguishing monitor. This intelligent architecture enables cost-effective scaling and simple installation.

  • Centralised management: All system components can be operated and configured via the HMI in the MAIN control cabinet.
  • Grows with your requirements: Start small and expand the system at any time.
  • Simple networking: Reliable connection via standard network cables.

Maximum operational flexibility

Whether directly at the control cabinet, via a wired control panel or using the long-range wireless remote control – you decide how you want to control your monitors. The highlight: every control element can be connected to any MAIN or SUB control cabinet in the network. This means the control system is always available exactly where you need it.

  • Free choice: radio remote control (up to 200 m) or wired control panel
  • Decentralised control: operate the entire system from any control point.
  • Intuitive operation: Fast and safe response in an emergency

Seamless integration and maximum security

The SCON control system is designed to integrate perfectly into your existing security infrastructure. Numerous interfaces enable connection to fire alarm panels or higher-level control systems. Optionally available Alarm inputs allow the triggering of pre-programmed extinguishing scenarios, whilst a VPN gateway enables remote maintenance and diagnostics. An optional uninterruptible power supply (UPS) ensures maximum operational reliability even in the event of a power cut.

  • Smart connectivity: Interfaces for control systems (potential-free contacts) and detection systems (Modbus TCP/IP)
  • Automated scenarios: Faster response thanks to predefined extinguishing sequences
  • Reliability: Optional UPS guarantees functionality when it matters most
Brochure

Fire monitor brochure

Download
(ca. 2.07 MB)

Image gallery

Technical documentation

Type size Download
Data sheetM1 MPN Download
Data sheetM1 AMPN Download
Data sheetM2-M7 FP-AFPD DC Download
Data sheetM2-M7 FP-FPD AC Download
Data sheetM2-M7 FP-FPD AC 3-Phase Download
Data sheetM2-M7 FP-FPD DC Download
Data sheetM2-M7 FP-FPD L+MO Download
Data sheetM2-M7 MPN AC Download
Data sheetM2-M7 MPN AC 3-Phase Download
Data sheetM2-M7 MPN DC Download
Data sheetM2-M7 MPN L+MO Download
Data sheetM2-M9 AMPN AC Download
Data sheetM2-M9 AMPN AC 3-Phase Download
Data sheetM2-M9 AMPN DC Download
Data sheetM2-M9 AMPN L+MO Download
Data sheetSU2-SU3 AC 3-Phase Download
Data sheetSU2-SU3 DC Download
Document Download
Data sheetDeclaration of conformity Download
Data sheetDeclaration of conformity ATEX Download
Document Download
Data sheetFM certificate Download
Data sheetDNV certificate Download

Frequently asked questions (FAQ)

We have compiled a list of the most frequently asked questions about our fire monitors. Click on the link below to find answers to questions regarding configuration, installation, applications and maintenance.

Go to the FAQ 'Extinguishing Monitors'

This might also be of interest for you:

Remote controlled monitors for stationary systems

The advantages: a targeted but flexible firefighting operation in limited areas

View more

FireDos services - Always there for you!

From planning to maintenance

View more

Containerised hazardous substances protected by fire monitors

Four monitors are installed at the port of Kokkola in Finland.

View more